{"_buckets": {"deposit": "dd762b94-5752-4063-a09c-c431604ed2c4"}, "_deposit": {"created_by": 1, "id": "24898", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "24898"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00024898", "sets": ["2404"]}, "author_link": ["72151", "72154", "72152", "72153"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-06-17", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "18", "bibliographicPageStart": "66-1", "bibliographicVolumeNumber": "8", "bibliographic_titles": [{"bibliographic_title": "Lubricants"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "There are two types of friction modifiers (FMs) used as lubricant additives: Reaction film FMs (RF-FMs) and adsorption film FMs (AF-FMs). While RF-FMs provide good performance in severe conditions, AF-FMs excel in mild conditions. This empirical evidence leads us to combine these two FMs to cover broader conditions. However, the e ects of their combination are highly complicated due to the interaction between these FMs. If the interaction force of AF-FMs with various materials can be evaluated, it would help us to improve tribological performances of lubricants. Although atomic force microscopy seems suitable for this application, we found some obstacles, such as fluid resistance, electrostatic force, and laser positioning of the cantilever, to achieve proper measurements of the adsorption force. In this study, the adsorption force between the polar group and the surface was directly measured in oil with a 1 nm silica probe modified with CH3 or COOH. This paper proposed how to eliminate errors included in the adsorption force measurement using AFM and a calibration method for obtaining an accurate adsorption force of the polar group, and a test of normality of the measured data was conducted by 400 measurements. As a result, it was shown that approximately 100 tests were needed to obtain an accurate adsorption force in this study.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "MDPI AG"}]}, "item_10001_relation_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "TD10121880", "subitem_relation_type_select": "NCID"}}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.3390/lubricants8060066", "subitem_relation_type_select": "DOI"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "20754442", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_b1a7d7d4d402bcce", "subitem_version_type": "AO"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yagi, Wataru"}], "nameIdentifiers": [{"nameIdentifier": "72151", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Honda, Tomomi"}], "nameIdentifiers": [{"nameIdentifier": "72152", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamura, Kazushi"}], "nameIdentifiers": [{"nameIdentifier": "72153", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Narita, Keiichi"}], "nameIdentifiers": [{"nameIdentifier": "72154", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-08-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "bd10121880.pdf", "filesize": [{"value": "6.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "(C)2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.", "licensetype": "license_free", "mimetype": "application/pdf", "size": 6400000.0, "url": {"label": "bd10121880.pdf", "url": "https://u-fukui.repo.nii.ac.jp/record/24898/files/bd10121880.pdf"}, "version_id": "08ec9d81-7b86-47da-b305-3ec402c95abd"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "friction modifiers (FMs)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "adsorption force measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "atomic force microscopy (AFM)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "colloid probe", "subitem_subject_scheme": "Other"}, {"subitem_subject": "calibration", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "other", "resourceuri": "http://purl.org/coar/resource_type/c_1843"}]}, "item_title": "Study on the Quantitative Evaluation of the Surface Force Using a Scanning Probe Microscope", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Study on the Quantitative Evaluation of the Surface Force Using a Scanning Probe Microscope"}]}, "item_type_id": "10001", "owner": "1", "path": ["2404"], "permalink_uri": "http://hdl.handle.net/10098/10947", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-07-01"}, "publish_date": "2020-07-01", "publish_status": "0", "recid": "24898", "relation": {}, "relation_version_is_last": true, "title": ["Study on the Quantitative Evaluation of the Surface Force Using a Scanning Probe Microscope"], "weko_shared_id": -1}
Study on the Quantitative Evaluation of the Surface Force Using a Scanning Probe Microscope
http://hdl.handle.net/10098/10947
http://hdl.handle.net/10098/109479592e719-d80a-465d-a6ca-e6209acfbacf
名前 / ファイル | ライセンス | アクション |
---|---|---|
bd10121880.pdf (6.4 MB)
|
(C)2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-01 | |||||
タイトル | ||||||
タイトル | Study on the Quantitative Evaluation of the Surface Force Using a Scanning Probe Microscope | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | friction modifiers (FMs) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | adsorption force measurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | atomic force microscopy (AFM) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | colloid probe | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | calibration | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_1843 | |||||
資源タイプ | other | |||||
著者 |
Yagi, Wataru
× Yagi, Wataru× Honda, Tomomi× Tamura, Kazushi× Narita, Keiichi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | There are two types of friction modifiers (FMs) used as lubricant additives: Reaction film FMs (RF-FMs) and adsorption film FMs (AF-FMs). While RF-FMs provide good performance in severe conditions, AF-FMs excel in mild conditions. This empirical evidence leads us to combine these two FMs to cover broader conditions. However, the e ects of their combination are highly complicated due to the interaction between these FMs. If the interaction force of AF-FMs with various materials can be evaluated, it would help us to improve tribological performances of lubricants. Although atomic force microscopy seems suitable for this application, we found some obstacles, such as fluid resistance, electrostatic force, and laser positioning of the cantilever, to achieve proper measurements of the adsorption force. In this study, the adsorption force between the polar group and the surface was directly measured in oil with a 1 nm silica probe modified with CH3 or COOH. This paper proposed how to eliminate errors included in the adsorption force measurement using AFM and a calibration method for obtaining an accurate adsorption force of the polar group, and a test of normality of the measured data was conducted by 400 measurements. As a result, it was shown that approximately 100 tests were needed to obtain an accurate adsorption force in this study. | |||||
書誌情報 |
Lubricants 巻 8, 号 6, p. 66-1-18, 発行日 2020-06-17 |
|||||
出版者 | ||||||
出版者 | MDPI AG | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 20754442 | |||||
書誌レコードID | ||||||
識別子タイプ | NCID | |||||
関連識別子 | TD10121880 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/lubricants8060066 | |||||
著者版フラグ | ||||||
出版タイプ | AO | |||||
出版タイプResource | http://purl.org/coar/version/c_b1a7d7d4d402bcce |