{"created":"2023-05-15T10:29:10.625744+00:00","id":25065,"links":{},"metadata":{"_buckets":{"deposit":"1a0178db-842a-4f87-8c70-2f6bb0ff2f06"},"_deposit":{"created_by":1,"id":"25065","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"25065"},"status":"published"},"_oai":{"id":"oai:u-fukui.repo.nii.ac.jp:00025065","sets":["2403:2226:2238:2285"]},"author_link":["72611","72605","72604","72599","72597","72600","72609","72606","72601","72603","72607","72610","72612","72608","72602","72598"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"188","bibliographicPageStart":"181","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"福井大学工学部研究報告"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper, we have studied the improvement method of the Computed Radiography(CR) images. The picture quality of CR image degrades with scattered radiation. This problem can be sett1ed using a grid, but a dose is increase. We examined the signal processing fi1ters which substitutes for the grid. We tried a Kasvand-type unsharp masking which combined the Kasvand operator with the conventional unsharp masking. We could improve a picture quality of CR images which cannot be improved by a conventional unsharp masking.","subitem_description_type":"Abstract"}]},"item_10002_relation_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"TD00004601","subitem_relation_type_select":"NCID"}}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"4298373","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"藤本, 博久"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"西野, 順二"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小高, 知宏"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小倉, 久和"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福島, 哲弥"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田中, 雅人"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小室, 裕冉"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石井, 靖"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"FUJIMOTO, Hirohisa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NISHINO, Junji"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ODAKA, Tomohiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OGURA, Hisakazu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"FUKUSHIMA, Tetsuya"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TANAKA, Masato"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOMURO, Hiroyuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ISHII, Yasushi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-08-05"}],"displaytype":"detail","filename":"AN00215401-047-01-016.pdf","filesize":[{"value":"11.7 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00215401-047-01-016.pdf","url":"https://u-fukui.repo.nii.ac.jp/record/25065/files/AN00215401-047-01-016.pdf"},"version_id":"c312998e-9f64-4ecf-8380-c94edcfbb195"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"CR","subitem_subject_scheme":"Other"},{"subitem_subject":"Computed Radiography","subitem_subject_scheme":"Other"},{"subitem_subject":"Unsharp Masking","subitem_subject_scheme":"Other"},{"subitem_subject":"Kasvand Operater","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"腹部CR画像における画質改善の試み","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"腹部CR画像における画質改善の試み"},{"subitem_title":"Improvement Method of Computed Radiography Image","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"1","path":["2285"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-06-14"},"publish_date":"2011-06-14","publish_status":"0","recid":"25065","relation_version_is_last":true,"title":["腹部CR画像における画質改善の試み"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T12:24:21.148252+00:00"}