{"_buckets": {"deposit": "c78d1e8a-40a7-46f0-8d6b-bdb7e8411737"}, "_deposit": {"created_by": 15, "id": "29018", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "29018"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00029018", "sets": ["2831"]}, "author_link": ["82145", "82146", "82147"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "188", "bibliographicVolumeNumber": "2002", "bibliographic_titles": [{"bibliographic_title": "遠赤外技術に関する国際シンポジウム"}, {"bibliographic_title": "Proceedings of 2nd International Workshop on Far Infrared Technologies", "bibliographic_titleLang": "en"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "It is known that the gyration output frequency varies with a long time CW operation. When the condition for the operation is the s~rne as the magnetic field and accelerating voltage, output frequency depends on radials of cavity. Generally, electromagnetic wave in the cavity makes a loss and this energy is changed into thermal. This effect changes cavity size. In this experiment, we measure the relation between output frequency and cavity temperature. In measurement system, ・the output frequency is measured by a heterodyne receiving system.\nHowever, cavity temperature can\u0027t be measured directly. So we measure cavity cooling.water temperature to calculate cavity temperature. As the result of this experiment, when the output power is 4W, the drift of output frequency is 71 MHz and the increase of the water temperature is by 1.3 degrees. And when output power is 8W, drift of output frequency is 119 MHz and the increase of water temperature is by 2.0 degrees. This result shows that the cavity radius and frequency depend on the power of electromagnetic wave at cavity.", "subitem_description_type": "Abstract"}]}, "item_10003_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Research Center for Development of Far Infrared Region,Fukui University"}]}, "item_10003_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Research Center for Development of Far Infrared Region,Fukui University"}]}, "item_10003_text_25": {"attribute_name": "その他のID", "attribute_value_mlt": [{"subitem_text_value": "TD10126071"}]}, "item_10003_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Iwata, Y", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "82145", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogawa, I", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "82146", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Idehara, T", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "82147", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "BD10126071.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1900000.0, "url": {"url": "https://u-fukui.repo.nii.ac.jp/record/29018/files/BD10126071.pdf"}, "version_id": "93899f5f-e9f2-473a-b11e-33475278a43a"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Frequency shift in a long CW operation of gyrotron", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Frequency shift in a long CW operation of gyrotron"}, {"subitem_title": "Frequency shift in a long CW operation of gyrotron", "subitem_title_language": "en"}]}, "item_type_id": "10003", "owner": "15", "path": ["2831"], "permalink_uri": "http://hdl.handle.net/10098/00028890", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-01-11"}, "publish_date": "2022-01-11", "publish_status": "0", "recid": "29018", "relation": {}, "relation_version_is_last": true, "title": ["Frequency shift in a long CW operation of gyrotron"], "weko_shared_id": -1}
Frequency shift in a long CW operation of gyrotron
http://hdl.handle.net/10098/00028890
http://hdl.handle.net/10098/000288906dba89ed-9331-4d85-adf9-3eb4ee4a9e9a
名前 / ファイル | ライセンス | アクション |
---|---|---|
BD10126071.pdf (1.9 MB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-01-11 | |||||
タイトル | ||||||
タイトル | Frequency shift in a long CW operation of gyrotron | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Frequency shift in a long CW operation of gyrotron | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
著者 |
Iwata, Y
× Iwata, Y× Ogawa, I× Idehara, T |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | It is known that the gyration output frequency varies with a long time CW operation. When the condition for the operation is the s~rne as the magnetic field and accelerating voltage, output frequency depends on radials of cavity. Generally, electromagnetic wave in the cavity makes a loss and this energy is changed into thermal. This effect changes cavity size. In this experiment, we measure the relation between output frequency and cavity temperature. In measurement system, ・the output frequency is measured by a heterodyne receiving system. However, cavity temperature can't be measured directly. So we measure cavity cooling.water temperature to calculate cavity temperature. As the result of this experiment, when the output power is 4W, the drift of output frequency is 71 MHz and the increase of the water temperature is by 1.3 degrees. And when output power is 8W, drift of output frequency is 119 MHz and the increase of water temperature is by 2.0 degrees. This result shows that the cavity radius and frequency depend on the power of electromagnetic wave at cavity. |
|||||
書誌情報 |
遠赤外技術に関する国際シンポジウム en : Proceedings of 2nd International Workshop on Far Infrared Technologies 巻 2002, p. 188, 発行日 2002 |
|||||
出版者 | ||||||
出版者 | Research Center for Development of Far Infrared Region,Fukui University | |||||