WEKO3
アイテム
{"_buckets": {"deposit": "c30cedf4-f4e1-4bc7-ab50-bc7a919a974d"}, "_deposit": {"created_by": 1, "id": "22971", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "22971"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00022971", "sets": ["2480"]}, "author_link": ["66999", "66998"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "39", "bibliographicPageStart": "38", "bibliographic_titles": [{}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this study, we measured and compared the word intelligibility of air conductive and bone conductive sound when wearing ear plugs in both ears by speech audiometry. The correct responses of word intelligibility of bone conductive sound tended to be better than those of sound heard through air conduction even in a high signal-to-noise environment. This effect was only elicited when ear plugs were used in both ears.", "subitem_description_type": "Abstract"}]}, "item_10003_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "2015 IEEE 4th Global Conference on Consumer Electronics. GCCE 2015 in Osaka Int\u0027l Convention Ctr. Oct. 27th-30th", "subitem_description_type": "Other"}]}, "item_10003_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_10003_relation_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "TD00007974", "subitem_relation_type_select": "NCID"}}]}, "item_10003_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takuma, Fujimoto"}], "nameIdentifiers": [{"nameIdentifier": "66998", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mikio, Mori"}], "nameIdentifiers": [{"nameIdentifier": "66999", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-08-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "1570166999-1.pdf", "filesize": [{"value": "631.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "(c)2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.", "licensetype": "license_free", "mimetype": "application/pdf", "size": 631100.0, "url": {"label": "1570166999-1.pdf", "url": "https://u-fukui.repo.nii.ac.jp/record/22971/files/1570166999-1.pdf"}, "version_id": "d87a0ddc-4837-488d-affb-dbfd8ce19016"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "word intelligibility", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bone conduction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "speech audiometry", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ear plug", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Word Intelligibility of Bone Conductive Sound When Wearing Ear Plugs", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Word Intelligibility of Bone Conductive Sound When Wearing Ear Plugs"}]}, "item_type_id": "10003", "owner": "1", "path": ["2480"], "permalink_uri": "http://hdl.handle.net/10098/9373", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-01-04"}, "publish_date": "2016-01-04", "publish_status": "0", "recid": "22971", "relation": {}, "relation_version_is_last": true, "title": ["Word Intelligibility of Bone Conductive Sound When Wearing Ear Plugs"], "weko_shared_id": -1}
Word Intelligibility of Bone Conductive Sound When Wearing Ear Plugs
http://hdl.handle.net/10098/9373
http://hdl.handle.net/10098/9373f7c16f9e-f3f1-4bd4-b1fc-ae4140bd817d
名前 / ファイル | ライセンス | アクション |
---|---|---|
1570166999-1.pdf (631.1 kB)
|
(c)2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-01-04 | |||||
タイトル | ||||||
タイトル | Word Intelligibility of Bone Conductive Sound When Wearing Ear Plugs | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | word intelligibility | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | bone conduction | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | speech audiometry | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ear plug | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
著者 |
Takuma, Fujimoto
× Takuma, Fujimoto× Mikio, Mori |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, we measured and compared the word intelligibility of air conductive and bone conductive sound when wearing ear plugs in both ears by speech audiometry. The correct responses of word intelligibility of bone conductive sound tended to be better than those of sound heard through air conduction even in a high signal-to-noise environment. This effect was only elicited when ear plugs were used in both ears. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2015 IEEE 4th Global Conference on Consumer Electronics. GCCE 2015 in Osaka Int'l Convention Ctr. Oct. 27th-30th | |||||