WEKO3
アイテム
{"_buckets": {"deposit": "4972c507-037e-43a0-9539-f0a096308ca3"}, "_deposit": {"created_by": 1, "id": "19883", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "19883"}, "status": "published"}, "_oai": {"id": "oai:u-fukui.repo.nii.ac.jp:00019883", "sets": ["2393"]}, "author_link": ["57303", "57298", "57302", "57299", "57301", "57300", "57297"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "166", "bibliographicPageStart": "162", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "MOLECULAR IMAGING AND BIOLOGY"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To evaluate the reproducibility of semi-quantitative parameters obtained from two FDG-PET studies using two different PET scanners. Methods: Forty-five patients underwent FDG-PET examination with two different PET scanners on separate days. Two PET images with different attenuation correction method were generated in each patient and three ROIs were placed on the lung tumor and normal organs (mediastinum and liver) in each image. Mean and maximum SUVs, tumor-to-mediastinum and tumor-to-liver ratios (T/M and T/L) and the percentage difference in parameters between 2 PET images (% Diff.) were compared. Results: All measured values except maximum SUV in the liver and tumor-related parameters (SUV in lung tumor, T/M, T/L) showed no significant difference between 2 PET images. Conclusion: The mean measured values showed high reproducibility and demonstrate that follow-up study or measurement of tumor response to anticancer drugs can be undertaken by FDG-PET examination without specifying the particular type of PET scanner.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "SPRINGER"}]}, "item_10001_relation_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "TD00006096", "subitem_relation_type_select": "NCID"}}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s11307-008-0132-9", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_18": {"attribute_name": "他の資源との関係", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "The original publication is available at www.springerlink.com"}]}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "15361632", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_b1a7d7d4d402bcce", "subitem_version_type": "AO"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "KAMIBAYASHI, Tomohito"}], "nameIdentifiers": [{"nameIdentifier": "57297", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSUCHIDA, Tatsuro"}], "nameIdentifiers": [{"nameIdentifier": "57298", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "DEMURA, Yoshiki"}], "nameIdentifiers": [{"nameIdentifier": "57299", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSUJIKAWA, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "57300", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OKAZAWA, Hidehiko"}], "nameIdentifiers": [{"nameIdentifier": "57301", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KUDOH, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "57302", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KIMURA, Hirohiko"}], "nameIdentifiers": [{"nameIdentifier": "57303", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-08-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "manuscript_revised_repositry.pdf", "filesize": [{"value": "107.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 107800.0, "url": {"label": "manuscript_revised_repositry.pdf", "url": "https://u-fukui.repo.nii.ac.jp/record/19883/files/manuscript_revised_repositry.pdf"}, "version_id": "6457cf86-6299-499f-aa4f-74c05997629d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "PET", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PET/CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reproducibility", "subitem_subject_scheme": "Other"}, {"subitem_subject": "standardized uptake value", "subitem_subject_scheme": "Other"}, {"subitem_subject": "lung tumor", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "other", "resourceuri": "http://purl.org/coar/resource_type/c_1843"}]}, "item_title": "Reproducibility of semi-quantitative parameters in FDG-PET using two different PET scanners: Influence of attenuation correction method and examination interval", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Reproducibility of semi-quantitative parameters in FDG-PET using two different PET scanners: Influence of attenuation correction method and examination interval"}]}, "item_type_id": "10001", "owner": "1", "path": ["2393"], "permalink_uri": "http://hdl.handle.net/10098/2121", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-08-27"}, "publish_date": "2009-08-27", "publish_status": "0", "recid": "19883", "relation": {}, "relation_version_is_last": true, "title": ["Reproducibility of semi-quantitative parameters in FDG-PET using two different PET scanners: Influence of attenuation correction method and examination interval"], "weko_shared_id": -1}
Reproducibility of semi-quantitative parameters in FDG-PET using two different PET scanners: Influence of attenuation correction method and examination interval
http://hdl.handle.net/10098/2121
http://hdl.handle.net/10098/212165a3ace3-086a-47d5-90b8-e5526fa4411c
名前 / ファイル | ライセンス | アクション |
---|---|---|
manuscript_revised_repositry.pdf (107.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-08-27 | |||||
タイトル | ||||||
タイトル | Reproducibility of semi-quantitative parameters in FDG-PET using two different PET scanners: Influence of attenuation correction method and examination interval | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PET | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PET/CT | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | reproducibility | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | standardized uptake value | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | lung tumor | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_1843 | |||||
資源タイプ | other | |||||
著者 |
KAMIBAYASHI, Tomohito
× KAMIBAYASHI, Tomohito× TSUCHIDA, Tatsuro× DEMURA, Yoshiki× TSUJIKAWA, Tetsuya× OKAZAWA, Hidehiko× KUDOH, Takashi× KIMURA, Hirohiko |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To evaluate the reproducibility of semi-quantitative parameters obtained from two FDG-PET studies using two different PET scanners. Methods: Forty-five patients underwent FDG-PET examination with two different PET scanners on separate days. Two PET images with different attenuation correction method were generated in each patient and three ROIs were placed on the lung tumor and normal organs (mediastinum and liver) in each image. Mean and maximum SUVs, tumor-to-mediastinum and tumor-to-liver ratios (T/M and T/L) and the percentage difference in parameters between 2 PET images (% Diff.) were compared. Results: All measured values except maximum SUV in the liver and tumor-related parameters (SUV in lung tumor, T/M, T/L) showed no significant difference between 2 PET images. Conclusion: The mean measured values showed high reproducibility and demonstrate that follow-up study or measurement of tumor response to anticancer drugs can be undertaken by FDG-PET examination without specifying the particular type of PET scanner. | |||||
書誌情報 |
MOLECULAR IMAGING AND BIOLOGY 巻 10, 号 3, p. 162-166, 発行日 2008-05 |
|||||
出版者 | ||||||
出版者 | SPRINGER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 15361632 | |||||
書誌レコードID | ||||||
識別子タイプ | NCID | |||||
関連識別子 | TD00006096 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s11307-008-0132-9 | |||||
他の資源との関係 | ||||||
関連名称 | The original publication is available at www.springerlink.com | |||||
著者版フラグ | ||||||
出版タイプ | AO | |||||
出版タイプResource | http://purl.org/coar/version/c_b1a7d7d4d402bcce |